After-sales service
*Growatt inverters have obtained more than 20 certifications around the world, and the products have been sold to more than 100 countries and regions in Australia, Europe, America, Asia, Africa, and Latin America on a large scale.
*After-sales stations are located in more than 20 countries around the world.
Products Description
Key Features:
●UPS function, 10ms transition
●100% three-phase imbalance output
●Smart phase-level export limitation function
●AC-coupled function compatible with third-party Inverter
●1.5 DC/AC ratio, 10kW system with 15kW solar input
●13.5A solar input current for high power modules
●Self-diagnostic function for easy installation and commission
●VPP interface ready
●Scalable system configuration
●Safety standard set by LCD directly
Datasheet
|
SPH4000TL3 BH-UP
|
SPH5000TL3 BH-UP
|
SPH6000TL3 BH-UP
|
SPH7000TL3 BH-UP
|
SPH8000TL3 BH-UP
|
SPH10000TL3 BH-UP
|
Input data(PV)
|
Max. recommended PV power(for module STC)
|
6000W
|
7500W
|
9000W
|
10500W
|
12000W
|
15000W
|
Max. DC voltage
|
1000
|
Start voltage
|
120V
|
MPP voltage range
|
120V-1000V/600V
|
No. of MPP trackers
|
2
|
No. of PV strings per MPP tracker
|
1
|
Max. input current per MPP tracker
|
13.5A
|
Max. short-circuit current per MPP tracker
|
16.9A
|
Output data(AC)
|
AC nominal power
|
4000W
|
5000W
|
6000W
|
7000W
|
8000W
|
10000W
|
Max. AC apparent power
|
4000VA
|
5000VA
|
6000VA
|
7000VA
|
8000VA
|
10000VA
|
Nominal AC voltage (range)
|
230V/400V (310~476V)
|
AC grid frequency (range)
|
50Hz/60Hz (45Hz-55Hz/55Hz-65Hz)
|
Max. output current
|
6.1A
|
7.6A
|
9.1A
|
10.6A
|
12.1A
|
15.2A
|
Adjustable power factor
|
0.8leading…0.8lagging
|
THDi
|
<3%
|
AC grid connection type
|
3W+N+PE
|
Battery data (DC)
|
Battery voltage range
|
100~550V
|
Max charging and discharging current
|
25A
|
Continuous charging and discharging power
|
4000W
|
5000W
|
6000W
|
7000W
|
8000W
|
10000W
|
Type of battery
|
Lithium /Lead-acid
|
Backup power(AC)
|
Max. AC output power
|
4000W
|
5000W
|
6000W
|
7000W
|
8000W
|
10000W
|
Max. output current
|
6.1A
|
7.6A
|
9.1A
|
10.6A
|
12.1A
|
15.2A
|
Nominal AC output voltage
|
230V/400V
|
Nominal AC output frequency
|
50/60HZ
|
THDv
|
<3%
|
Switch time
|
<10ms
|
Efficiency
|
MAX. efficiency
|
97.6%
|
97.80%
|
98.0%
|
98.2%
|
98.2%
|
98.2%
|
European efficiency
|
97%
|
97.2%
|
97.30%
|
97.40%
|
97.40%
|
97.50%
|
Protection devices
|
DC switch
|
Yes
|
DC reverse polarity protection
|
Yes
|
AC/DC surge protection
|
Yes
|
Battery reverse protection
|
Yes
|
AC short-circuit protection
|
Yes
|
Ground fault monitoring
|
Yes
|
Grid monitoring
|
Yes
|
Anti-islanding protection
|
Yes
|
Residual-current monitoring unit
|
Yes
|
Insulation resistance monitoring
|
Yes
|
Product Application